PainFree — Better Life

Evidence brief for clinic investors

PEMF for fatigue in multiple sclerosis: what the research shows

Young woman lying exhausted on a blue sofa, everyday fatigue

Fatigue is one of the most commonly reported symptoms of multiple sclerosis (MS). The verified research on pulsed electromagnetic field (PEMF) technology for MS fatigue is two placebo-controlled trials: a 37-patient pilot from Germany and a 117-patient crossover trial at three US sites. This brief sets out what each one measured, what it did not, and where the evidence stops.

What the trials measured

Randomized, patient- and rater-blinded, placebo-controlled pilot trial, 37 patients with relapsing-remitting MS and significant fatigue, 12 weeks (Piatkowski et al., Journal of Alternative and Complementary Medicine, 2009). Patients used one commercial pulsed magnetic-field system for 8 minutes twice daily, or a placebo, for 12 weeks. On the primary outcome, the Modified Fatigue Impact Scale (MFIS, lower is less fatigue), the score after 12 weeks was 26.84 in the active group versus 36.67 in the placebo group (p=0.024). On the Fatigue Severity Scale (FSS) it was 3.5 versus 4.7 (p=0.016). After 6 weeks' follow-up off treatment, the active and placebo groups did not differ in fatigue (MFIS, FSS). The treatment was well tolerated. (PubMed 19422286)

Multi-site, double-blind, placebo-controlled crossover trial, 117 completers with clinically definite MS (81% of the initial sample), 4 weeks active and 4 weeks placebo with a 2-week washout (Lappin et al., Alternative Therapies in Health and Medicine, 2003). Sites were the University of Washington Medical Center in Seattle, the Neurology Center of Fairfax in Virginia and the Multiple Sclerosis Association of America in Cherry Hill, New Jersey. On the MS Quality of Life Inventory (MSQLI), improvements in fatigue and overall quality of life were significantly greater on the active device. There was no treatment effect on bladder control or on a disability composite, and results for spasticity were mixed. The authors wrote that the clinical effects were small and need to be replicated. The abstract gives no numeric values. (PubMed 12868251)

Where the evidence stops

What to ask when you evaluate a clinic model

  1. Does any MS claim rest on more than these two trials? Ask for the study, and read it.
  2. When the 2009 fatigue scores are quoted, is the 6-week follow-up quoted with them, showing the difference had gone?
  3. Is the protocol the clinic would use the one that was tested, or a different one?
  4. MS is managed by neurologists. How will the clinic coordinate with each client's neurologist, and make clear that it does not replace disease-modifying treatment?
  5. How will fatigue outcomes be recorded for every client, not only those who do well?

Questions buyers ask

How much research is there on PEMF for multiple sclerosis fatigue?

Little. The verified evidence is two placebo-controlled trials: a 37-patient pilot published in 2009 by Piatkowski and colleagues in Germany, and a 117-patient crossover trial at three US sites published in 2003 by Lappin and colleagues.

What did the trials measure?

Fatigue questionnaires. The 2009 pilot used the Modified Fatigue Impact Scale and the Fatigue Severity Scale after 12 weeks of treatment and again 6 weeks after treatment stopped. The 2003 trial used the MS Quality of Life Inventory, which covers fatigue, bladder control, spasticity and overall quality of life, after 4 weeks on each device.

Does any benefit last after treatment stops?

The evidence does not show that it does. The 2009 pilot checked again 6 weeks after treatment stopped (the result is in its study summary above), and the 2003 trial reported no follow-up after treatment.

Is TMS the same as PEMF?

No. Transcranial magnetic stimulation is a different technology with its own research. TMS studies in multiple sclerosis are not evidence for PEMF, and this brief does not use them.

Is there an FDA indication for PEMF in multiple sclerosis fatigue?

No FDA decision we know of covers PEMF for multiple sclerosis or its fatigue. See the regulatory section below.

The regulatory side

FDA decisions on PEMF devices are specific to one device, one model and one indication, and they do not carry over to other devices. No FDA decision we know of covers PEMF for multiple sclerosis or its fatigue. Before you rely on any device for a clinic, look up its own FDA record. Our guide PEMF and the FDA explains how, and what the technology's record since 1979 does and does not cover.

Read the research yourself

Every study above links to its PubMed abstract. More published PEMF studies, each checked against the original paper: pemf-research.com. Compare with our insomnia and neuropathic pain briefs.

About the publisher

These guides are written by PainFree. PainFree has run pain-relief clinics in Israel for 25 years, and more than 70 operate today; its Israeli site, in Hebrew, is painfree.org.il. We would want any buyer to read the evidence behind a clinic model this carefully, ours included.

Related research on this site

This article is general information for prospective business owners. It is not legal, financial or medical advice. We do not make earnings claims, and this page is not an offer to sell a franchise or a business opportunity. Study results describe the trials cited, not any particular device or clinic. Equipment supplied to US clinics will meet the applicable US regulatory requirements.