PainFree — Better Life

Evidence brief for clinic investors

Pelvic floor magnetic stimulation for urinary incontinence in women: what the research shows

A woman in conversation with a clinician in scrubs in a clinic waiting area

Chair-based pelvic floor magnetic stimulation is a high-intensity technology: the woman sits fully clothed on a chair that delivers fields strong enough to stimulate the pelvic nerves and make the pelvic floor muscles contract. It has a larger body of sham-controlled trials than most "magnetic" therapies, and it is not low-intensity pulsed electromagnetic field (PEMF) therapy. This brief sets out what the trials in women with stress and urgency incontinence measured, the trials that found no difference, and what the reviews say about how certain the evidence is. If you are weighing a clinic business that offers PEMF, this is what was tested, by which technology, and where the evidence stops.

How big the problem is

The National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK), part of the NIH, says bladder control problems are common, especially in women, and that researchers estimate approximately half of all women experience urinary incontinence. It says women are more likely to develop it during and after pregnancy, childbirth and menopause (NIDDK, Definition & Facts for Bladder Control Problems).

A note on terms: this is not PEMF

"Magnetic therapy" covers several different technologies, and a result for one does not carry over to another. The trials in this brief tested high-intensity magnetic stimulation of the pelvic floor or the sacral nerve roots. Its authors call it extracorporeal magnetic innervation (ExMI), functional or pulsed magnetic stimulation, high-inductive or high-intensity focused electromagnetic stimulation. One trial below reports a peak of 560 mT and another an induction intensity of 2.5 T; at these strengths the field induces currents that make the pelvic floor contract. Low-intensity PEMF uses far weaker pulsed fields and is not designed to make muscles contract, so none of these results can be quoted as a PEMF result. Static magnets, which produce no pulsed field at all, are a third technology; one placebo-controlled trial of them is listed below for completeness. Each study is labelled with the technology its authors describe.

Trials measure incontinence with a bladder diary (leaks per day or week), a pad test (grams of urine lost) and questionnaires such as the International Consultation on Incontinence Questionnaire short form (ICIQ-UI SF). Stress incontinence is leakage on coughing, laughing or exertion; urgency incontinence is leakage with a sudden urge to void.

Stress incontinence: sham-controlled trials

Null overall. Double-blind randomized trial, 70 women with urodynamically confirmed stress incontinence (Gilling et al., BJU International, 2009, Tauranga Hospital, New Zealand). Chair-based extracorporeal electromagnetic stimulation (35 women) against sham (35 women), three sessions a week for 6 weeks; primary outcome a 20-minute provocative pad test. Both groups improved from baseline, and at 8 weeks the improvements in the active group were not statistically significant when compared with sham. The authors conclude that stimulation was no more effective overall than sham. In the subgroup of women who could not generate an adequate pelvic floor contraction at the start, pad-test leakage fell more with active stimulation than with sham (P < 0.05). (PubMed 19154474)

Double-blind randomized sham-controlled trial, 120 women with stress incontinence (Lim et al., Journal of Urology, 2017, Penang, Malaysia). Pulsed magnetic stimulation, 2 sessions a week for 2 months (16 sessions). The response criterion was a 5-point drop in ICIQ-UI SF score. At 2 months, 45 of 60 women (75%) on active stimulation and 13 of 60 (21.7%) on sham were responders (p <0.001). After 2 months women could opt for 16 more active sessions whatever their original group, so the 14-month figures (75.0% after 32 active sessions, 72.2% and 68.3% after 16, and 21.1% of the 19 who never had active stimulation) are no longer a randomized comparison. (PubMed 27871927)

Null on the primary outcome. Randomized sham-controlled trial, 39 women with urodynamic stress incontinence not cured by pelvic floor muscle training (Yamanishi et al., Low Urinary Tract Symptoms, 2019, Dokkyo Medical University, Japan). Magnetic stimulation for 10 weeks, randomized 2:1. Nine women dropped out, leaving 18 active and 12 sham. The primary outcome, incontinence episodes per week, improved from baseline in the active group but did not differ significantly between groups. Between-group differences were significant only for the ICIQ-SF total score and abdominal leak point pressure (P < .05); no other parameter differed. (PubMed 28961380)

Placebo-controlled trial, 62 women with stress incontinence (Fujishiro et al., Journal of Urology, 2000, University of Tokyo). Repetitive magnetic stimulation of the sacral roots, 15 Hz for 30 minutes, with outcomes measured 1 week after stimulation. Leaks and pad-test urine loss decreased more with active than with sham stimulation (p = 0.0023 and 0.0377), and the improvement rate was 74% against 32% (p = 0.0009). This is a short-term result with one week of follow-up. (PubMed 10992380)

Single-session sham-controlled study, women with stress or mixed incontinence (Ptaszkowski et al., Journal of Clinical Medicine, 2020, Wroclaw Medical University). One 20-minute session of high-inductive electromagnetic stimulation at 2.5 T. Pelvic floor muscle activity on surface electromyography during contraction was higher than with sham straight after the session (p = 0.047) and 1 hour later (p = 0.017). It measured muscle activity, not leakage, and only after a single session. (PubMed 32210031)

Urgency incontinence and overactive bladder: sham-controlled trials

Multicenter randomized sham-controlled trial, 151 women with urgency incontinence (Yamanishi et al., International Journal of Urology, 2014, SMN-X Study Group, Japan). An armchair-type magnetic stimulator, 560 mT peak at 10 Hz, 25 minutes twice a week for 6 weeks, randomized 2:1; the sham delivered 20.4% of the active intensity at 1 Hz. Leaks per week fell by 13.08 with active and 8.68 with sham stimulation (P = 0.038), urgency episodes per day by 2.65 and 1.53 (P = 0.011). Apart from diarrhea and constipation, no device-related adverse event was reported. Note that the sham arm also improved substantially. (PubMed 24118165)

Randomized sham-controlled trial, 70 women with urgency incontinence (Lukanović et al., International Urogynecology Journal, 2026, Ljubljana University Medical Center). Magnetic stimulation, 12 sessions over 6 weeks, randomized 2:1; the sham group received minimal stimulation. At 6 months, ICIQ-UI SF scores improved by 4.05 points on active against 1.19 on sham (p < 0.001). Only 40 active and 16 sham participants completed the 6-month follow-up, and no serious adverse events were reported. The authors call for further high-quality trials with standardised protocols and longer follow-up. (PubMed 41400661)

Placebo-controlled trial, 37 women with urinary frequency and/or urge incontinence (Fujishiro et al., Journal of Urology, 2002, University of Tokyo). Sacral root magnetic stimulation, 15 Hz for 30 minutes, outcomes 1 week after stimulation. Leaks fell by 3.6 against 0.4 (p = 0.04) and mean urine volume per void rose by 23.5 ml against 6.2 ml (p = 0.04). One week of follow-up only. (PubMed 12187217)

Partly null. Single-blinded randomized sham-controlled trial, 56 women with overactive bladder, all taking mirabegron (Bele et al., Journal of Clinical Medicine, 2024, University Medical Centre Maribor). Extracorporeal magnetic stimulation, 16 sessions in 8 weeks, added to the drug, against sham plus the drug. Both groups improved, and end-point daytime frequency and nocturia did not differ significantly between groups. Weekly incontinence episodes fell by 3.8 against 2.5 at week 4 and by a further 3.3 against 0.4 at week 8 (p = 0.013). (PubMed 38337609)

The trials that found no difference

Null. Single-blinded placebo-controlled trial, 101 women aged 60 and over (Wallis et al., Clinical Medicine & Research, 2012, Griffith University, Australia). Static magnets, not pulsed stimulation: an undergarment with 15 static magnets (800 to 1200 Gauss) worn at least 12 hours a day for 3 months (50 women), against the same garment with inert metal disks (51 women). There were no statistically significant differences between groups in any outcome at 12 weeks, and an early subjective improvement did not hold up in sensitivity analysis. (PubMed 21817123)

Null between groups. Randomized pilot trial, 52 women with stress incontinence, average age 65 (Weber-Rajek et al., Clinical Interventions in Aging, 2018, Toruń, Poland). ExMI, 15 minutes three times a week for 4 weeks (28 women), against no intervention (24 women). Severity of incontinence improved within the ExMI group, but there were no statistically significant differences between the groups at the final assessment. (PubMed 30584287)

No difference from exercise. Randomized trial, 68 women with stress incontinence, 48 completed (Dudonienė et al., Journal of Clinical Medicine, 2023, Kaunas, Lithuania). Functional magnetic stimulation against pelvic floor muscle training for 6 weeks. Both groups improved on the ICIQ-SF and IIQ-7, scores did not differ significantly between groups, and no perineometry measure differed. Neither intervention was superior to the other in the short term. (PubMed 37176598)

What the pooled reviews say, and how certain they are

Systematic review, 8 randomized, blinded, sham-controlled trials, 494 patients (Lim et al., Neurourology and Urodynamics, 2015). Active stimulation made improved continence 2.3 times more likely than sham (95% CI 1.60 to 3.29), but the authors say this was subject to bias from varying inclusion criteria, poor reporting and variable time points; quality-of-life results conflicted, cure was reported by only one trial, and the longest follow-up was six months. 5% of patients had mild side effects. Their conclusion: there is no firm evidence to support magnetic stimulation in the management of urinary incontinence. (PubMed 25251335)

Systematic review and meta-analysis, 20 studies, 12 pooled (Hou et al., Journal of Advanced Nursing, 2020). Extracorporeal magnetic stimulation for stress incontinence. Only 8 of 17 randomized trials had low overall risk of bias, and all non-randomized controlled trials had serious risk of bias. Pooled effects favoured stimulation on quality of life, leakages, pad test and incontinence events, but high heterogeneity persisted, and the authors say inferences must be made with caution. (PubMed 32538469)

Meta-analysis, 6 randomized trials in female stress incontinence (Sun et al., Therapeutic Advances in Urology, 2021). Against placebo, magnetic stimulation lowered ICIQ scores (mean difference −3.93, 95% CI −5.85 to −2.01), reduced incontinence episodes (−1.42) and pad-test urine loss (−4.67), and had a higher objective cure rate (odds ratio 8.49, 95% CI 3.08 to 23.37). The authors say the best protocol has still to be established. (PubMed 34345251)

Partly null. Systematic review and meta-analysis, 17 studies, 1,389 women with stress incontinence (Li et al., International Journal of Gynecology & Obstetrics, 2026). Magnetic stimulation-centred treatment improved incontinence, quality of life, the 1-hour pad test and maximum urethral closure pressure, but did not differ from control on the 24-hour pad test or pelvic floor muscle strength. The authors cite the limited number and high heterogeneity of some outcomes and advise caution in using the results in practice. (PubMed 41346300)

Partly null. Systematic review and meta-analysis, 7 studies of high-intensity focused electromagnetic stimulation in women (Leonardo et al., Neurourology and Urodynamics, 2025). Incontinence episodes fell more than with control (mean difference −4.10, 95% CI −7.34 to −0.85) and ICIQ-UI SF improved (−3.03). Pelvic floor contraction and resting tone did not differ between groups (p = 0.25 and p = 0.30), and overall quality of life was statistically comparable (p = 0.09). The authors cite high heterogeneity and possible bias and call for trials with proper blinding. (PubMed 39760417)

Systematic review, 5 studies in women with urgency incontinence (Antić et al., International Urogynecology Journal, 2023). All five studies reported benefit, but each used different diagnostic and entry criteria, treatment regimens and methods, which made it impossible to compare the results. The authors call the literature lacking and ask for standardised trials with longer follow-up. (PubMed 36877276)

Network meta-analysis, 31 randomized trials, 1,900 women with stress incontinence, 8 conservative treatments (Li et al., Frontiers in Medicine, 2024). Ranked by probability of being best, magnetic stimulation came fifth of eight on ICIQ-UI SF improvement (SUCRA 45.3%) and seventh of eight on reducing urine leakage (SUCRA 27.8%), behind electrical stimulation, biofeedback and radiofrequency on symptom scores, and also behind laser and pelvic floor muscle training on leakage. The authors identify biofeedback electrical stimulation as the most effective overall. (PubMed 39703522)

Where the evidence stops

What to ask when you evaluate a clinic model

  1. When an incontinence claim cites "magnetic" research, which technology was tested: a high-intensity pelvic floor stimulation chair, sacral root stimulation, static magnets, or low-intensity PEMF?
  2. If the clinic would use PEMF equipment, does the seller say plainly that the incontinence trials tested a different, high-intensity technology?
  3. Does the seller cite the null and partly null results (Gilling 2009, Wallis 2012, the reviews' certainty warnings) alongside the positive ones?
  4. Will women be seen only after a physician has assessed the type and cause of incontinence, and alongside, never instead of, the care that physician directs, including pelvic floor muscle training?
  5. Will a bladder diary, a pad test or the ICIQ-UI SF be recorded at the start, at the end and months later, so the clinic knows whether any change lasts?
  6. Can the seller show you this research, with its gaps, the way it is written here?

Questions buyers ask

How common is urinary incontinence in US women?

The National Institute of Diabetes and Digestive and Kidney Diseases (NIH) says researchers estimate that approximately half of all women experience urinary incontinence, and that it is more likely during and after pregnancy, childbirth and menopause.

Is chair-based pelvic floor magnetic stimulation the same as PEMF?

No. Chair-based pelvic floor magnetic stimulation (ExMI, or high-intensity electromagnetic stimulation) uses fields strong enough to stimulate the pelvic nerves and make the pelvic floor muscles contract. Low-intensity PEMF uses much weaker pulsed fields and is not designed to contract muscle. A trial result for one does not carry over to the other.

Were there null results?

Yes. In the double-blind sham-controlled trial of Gilling 2009 (70 women with stress incontinence), active stimulation was no more effective overall than sham. A placebo-controlled trial of static pelvic magnets in 101 older women found no difference in any outcome, and an ExMI pilot in 52 women found no difference from an untreated control group at the end of the course.

What do the systematic reviews conclude?

The pooled short-term results point toward active stimulation over sham, but every review flags heterogeneity, risk of bias, short follow-up or non-standard protocols. A 2015 review of 8 sham-controlled trials found no firm evidence of benefit, and the longest follow-up was six months. We found no Cochrane review on this question.

Is any PEMF device FDA cleared for urinary incontinence?

No FDA decision we know of covers low-intensity PEMF for urinary incontinence. FDA decisions are specific to one device, one model and one indication; the section below explains where to check.

The regulatory side

FDA decisions on PEMF devices are specific to one device, one model and one indication, and they do not carry over to other devices. The technology's record began with bone growth stimulators approved through premarket approval (PMA P790002) in 1979; devices for pain and edema have gone through the 510(k) pathway under 21 CFR 890.5290(b). Neither covers urinary incontinence, and a decision for a high-intensity pelvic floor stimulation chair would not cover a PEMF device. Before you rely on any device for a clinic, look up its own FDA record. Our guide PEMF and the FDA explains how, and what the technology's record since 1979 does and does not cover.

Read the research yourself

Every study above links to its PubMed abstract. More published PEMF studies, each checked against the original paper: pemf-research.com. For pelvic pain in women, see our menstrual pain and chronic pelvic pain brief; for men, see the chronic prostatitis / chronic pelvic pain brief.

About the publisher

These guides are written by PainFree. PainFree has run pain-relief clinics in Israel for 25 years, and more than 70 operate today; its Israeli site, in Hebrew, is painfree.org.il. We would want any buyer to read the evidence behind a clinic model this carefully, ours included.

Related guides

This article is general information for prospective business owners. It is not legal, financial or medical advice. We do not make earnings claims, and this page is not an offer to sell a franchise or a business opportunity. Study results describe the trials cited, not any particular device or clinic. Equipment supplied to US clinics will meet the applicable US regulatory requirements.